Kipp & Zonen SP-Lite
This silicium-pyranometer was especially designed for calculating evapotranspiration for precision irrigation purposes, monitor solar panels in energy production, for air pollution dispersion calculations and similar applications. SP-Lite can be used under all weather conditions. It compares favorably to ISO 9060-specified First Class Thermopile Pyranometers under clear and unobstructed natural daylight conditions.
Technical specifications
SP-Lite uses a photo diode detector, which creates a voltage output that is proportional to the incoming radiation. This signal is converted by the integrated Adcon amplifier to a 0-2.5V signal, compatible to all Adcon RTU's.
The sensor comes complete with all mast mounting equipment, two pipe clamps, and a shielded 2m cable with a 7-pin Binder jack, compatible to all RTU's of the A723 and A733 families.
Ordering Information: 200.733.020
Kipp & Zonen CMP-3
CMP-3 is a pyranometer according to ISO-9060 Second Class standard. It is measuring the irradiance on a plane surface from radiant fluxes in the wavelength range from 310 to 2800nm by means of a thermopile element. This makes the CMP-3 ideal for meteorological routine measurements which require neither a First Class nor a Secondary Standard instrument.
The output signal of the thermopile sensor is converted by the integrated Adcon amplifier to a 0-2.5V signal, compatible to all Adcon RTU's. Technical specifications
Ordering Information: 200.733.022
The sensor comes complete with all mast mounting equipment, two pipe clamps, and a shielded 2m cable with a 7-pin Binder jack, compatible to all RTU's of the A723 and A733 families.
Albedometers, Pyrgeometers, Net Radiation,
First Class Sensors,
Secondary Standard
Adcon custom builds amplifiers for other products of Kipp & Zonen, such as the CMP-6, CG3 and NR1 sensors. The German Aerospace Center in Mecklenburg uses 15 Albedometers and 15 Pyrgeometers, built around an Adcon A740 addNODE weather station, for the ground truthing of satellite images. Tell your Adcon Distribution Partner about your project or contact us!
| Technical Specifications |
CMP-3 |
SP-Lite |
| Sensitivity |
5-20µV/Wm² |
100 µV/Wm² |
| Spectral Range |
310 - 2800nm |
400 - 1100nm |
| Max. Irradiance |
1400 W/m² |
2000 W/m² |
| T.C. of Sensitivity |
+/-5%
(-10°C - 40°C) |
+/- 0.15% /°C |
| Operating Temperature |
-40°C ... +80°C
-40°F ... +176°F |
-30°C ... +70°C
-22°F ... +158°F |
| Non-stability (change/year) |
+/-1% |
n.a. |
Non-linearity
(0-1000 W/m²) |
+/- 2.5% |
n.a. |
Tilt response
(at 1000 W/m²) |
+/- 3% |
n.a. |
|