Questions? Call us
+43 2243 38280-0
The all-new A753 addWAVE GSM/GPRS offers a wealth of new features and takes our hot-selling line of GSM RTUs to a whole new, professional level. Get more of everything! More resolution, more I/Os, more memory, more flexibility, etc.etc
The A753 GSM / GPRS RTU is a completely new design that surpasses its predecessor, the A733 GRPS, in every aspect. We have tried to build an RTU that can be used for a huge variety of applications, from basic to professional meteorology, from hydrographics to meter reading, from wind and solar power site assessments to rain intensity monitoring.
| Feature | A733 | NEW in A753 |
| SDI-12 Interface built-in | no | yes |
| # of SDI-12 Sensors supp. | 20 | 40 |
| Analog Resolution: | 10-bit | 16-bit |
| Sensor Excitation | Battery voltage | Battery voltage and preset voltage, stabilized |
| Measurement timing | synchronous | synchronous or asynchronous |
| Pulse counter frequency | 2 or 30 Hz | 3 x 50 Hz 1 x 600 Hz |
| Wind Gust monitoring | no | yes |
| Rain Intensity monitoring | no | yes |
| Integrated mV-Amplifier | no | yes |
| Memory | 32KB | 2MB |
| Firmware update without need to open case |
no | yes |
Here are a few examples
Just like its predecessor the A753 makes an excellent ag met station: very easy to install, setup and maintain, and fully backwards compatible - yet expandable to an unheard of extent!
Professional meteorologists want the best of it all. They want high resolution, WMO compliant measuring methods, particularly when it comes to wind speed and direction, flexibility to host many different sensors - and if that comes in a compact package at reasonable prices it doesn't hurt either! A753 can do all that and more
Most modern multi-parameter sensors for water and air quality come with a digital SDI-12 interface to increase accuracy and compatibility. A753 allows the operation of up to 40 SDI-12 values without any additional adapters. And for accurate analog sensors it features 12 0-2,5V inputs with 16-bit resolution.
In many countries rain intensity monitoring requires the stations capability to store date and time of every single pulse that occurs. Lots of data! The A753 can not only do that - it can furthermore store the wind speed and wind direction at the time of the pulse!
| Case | Aluminum, powder coated |
| Protection type | IP-67 |
| Dimensions & weight |
160 x 60 x 80 mm (6.3 x 2.4 x 3.1 inch) 1200g (2.5 lb) |
| Connectors for sensors and power | Made in Germany by Binder IP-67 protection class Sockets: brass, nickel plated Socket contacts: gold plated Protective caps 4 x M9 female 7-pin 1 x M9 female 5-pin |
| Antenna connector | TNC with external seal, water tight , Made in Germany |
| Mounting | Mast mounting bracket |
| Operating temperature | -20°C - +75°C |
| Input Channels | 60 total |
| Analog Inputs | 12 x 0 - 1V / 2.5V DC ( 3 of these inputs can be configured for a range of 0 - 150mV DC low temp.drift) |
| Digital Inputs | 40 x SDI-12 values |
| Counter Inputs | 2 + 2 I/O A + I/O D: for standard reed switches; electronical signal debouncing, e.g. for rain gauges; max. pulses per second: 30 I/O B + I/O C: for hi-speed pulses, e.g. wind speed sensors or flow meters; max. pulses per second: 500 |
| TTL Inputs / Outputs | 4 x TTL compatible status ports (input) or Switch (output) , user selectable (2 of which with 5V, 2 with 3.3V) |
| Resolution on analog ports | 16-Bit |
| Sensor Power Supply | User selectable: - Unregulated battery Voltage 5.5V - 7.5V - Stabilized Voltage: setable from 3.3V-7.5V |
| Memory | 2MB for up to 500.000 readings (depending on types of sensors attached) Example: ETo station, 15-minute values: almost 6 months |
| Wind Gust Monitoring | Port C + Adcon Wind Sensor: 4 x samples per second, 3-second average; Date/Time of top speed stored |
| Wind Vector Monitoring | Port C + Adcon Wind Sensor: Direction is measured at time of speed reading; direction is weighed by speed and stored as vector |
| Rain Intensity Monitoring | Port D + Pulse Rain Gauge (max. resolution is 1 second) Date / Time of every single pulse stored; if required up to 3 additional analog values and 2 counters can be stored, e.g. wind speed & direction plus temperature |
| Pressure Hammer Detection | Port C + Adcon Manometer Probe: permanently powered sensor measures 4 x per second for pressure hammers with a 3-sec. average |
| Low Voltage Amplifier | Port B: allows usage of sensors with mV output signals to be attached directly |
| Asynchronous sampling | To reduce interference caused by synchronously sampling all ports they can be turned on and off sequentially |
| Event Monitor | In order to detect status changes on a digital input the station can sample each digital port with a time resolution of 1 second; date and time of every single status change are logged. Application: error monitoring on equipment, intrusion detection, pump operation, etc. |
| Frequency range | 900 & 1800 MHz (Europe) and 850 & 1900 MHz (Americas) |
| Modem | Motorola G24L |
| SIM Card | small footprint |
| Security | SIM cards are PIN code protected! |
| Connection types | GSM: CSD Circuit Switched Data GPRS |
| GPRS Connect Frequency | User selectable: - permanent connection - connect from 1 x per minute to 1 x per day |
| Antenna | Omnidirectional |
| Power Supply | internal 6.2V battery, charged by solar panel or mains adaptor |
| Battery type | Panasonic High-Temperature Industrial Grade NiMH battery, 3100mAh |
| Approvals | FCC, R&TTE, CE, Industry Canada, Radio Australia |